We have done retrofit of existing AHU motor replaced IE5+ Motor by 25% energy saving.
Here we have done study in SKF and Fortis hospital IE5+ Motor retrofit job as follows:
Pls find below case study installation of ECTi IE5+ Motor, we got 25% savings by replacement of Induction motor and 12% savings by replacement of EC fans.
| ABB BALDOR EC TITANIUM IE-5+ MOTOR POWER SAVING REPORT Application: Centrifugal Oil Pump Customer : SKF, Bangalore | |||
| Description | Exisitng Motor | ABB Baldor IE5 Motor | |
| Make | CG | ABB Baldor-Reliance | |
| Model | Apex | ECS101M0H7FB4 | |
| Motor Enclosure | TEFC | TEFC | |
| Efficiency | IE3 – 92.1% | IE5 – 94 | |
| Power – KW | 5.5 | 5.5 | |
| Voltage | 415 | 460 | |
| Speed | 1464 | 1800 | |
| Amps | 27 | 17.4 | |
| Pole | 4 | 4 | |
| Hz | 50 | 60 | |
| Frame | 132S | 213TC | |
| Motor IP | IP55 | IP54 | |
| Motor Type | Squirrel Cage Induction | PM-FASR | |
| Power factor | 0.83 | 0.97 | |
| Power consumption(KW) | 5.5 | 4.1 | |
| Power saving per hour(KW) | 1.4 | ||
| Power saving per day(KW) | 33.6 | ||
| Power saving per Month(KW) | 1008 | ||
| Power saving cost per Month(Rs) SKF Unit Rate as Rs.7 | 7056 | ||
| Power saving per year(KW) | 12196.8 | ||
| Power saving cost per year(Rs) | 85377.6 | ||
| Motor Investment cost (Rs) | 85246 | ||
| ROI in Months | 9.9 | ||
| ROI in Year | 1.0 | ||
| Total Power Saving(%) | 25.5 | ||
| Plant Incharge Sign Date: 26.03.2025 | |||
By installing ABB motor, we are able to save more than 25 % of energy which is on the base line of existing motor, Pl validate all matrix and share the details to proceed further. This is special synchronous permanent magnet motor (PMSM). Thanks Medi for the support.
Area 1B services and Pump # S63 .
Existing Motor: Consumption: 4.58 Kw
ABB Motor: Consumption: 2.9 Kw